Ashly - MFA-8000 - 8 Ohms: 750 Watts RMS or 4 Ohms: 3000 Watts RMS mono


The MFA-8000 contains sophisticated power amp monitoring circuits to detect
abnormal conditions. A highly accurate detector illuminates the true CLIP L.E.D.
at the onset of clipping. Further increases in signal level will activate a limiter
circuit to prevent severe overload distortion from occurring, while an illuminated
LIMIT L.E.D. lets the user know that the function has been activated. Advanced
thermal management circuitry senses temperature at four different locations in
the amp and adjusts fan speed accordingly. A THERMAL L.E.D. on each channel
indicates an above normal operating temperature, while protective circuitry
automatically attenuates the input signal until the amplifier returns to within a
normal operating range. The amplifier's output will automatically shut-down in
the event of a fault condition such as severe overheating, shorted output, DC
voltage, or ultrahigh frequencies at the output. A PROTECT L.E.D. indicates
when one or more of these fault conditions occur. As alluded to previously,
each channel's limiting, thermal, and protection management is completely
independent of the other channel. Each channel also features a ten-segment
L.E.D. level meter on the front panel of the amplifier. Standard inputs to the
amp include balanced XLR (with a transformer available as an option), 1/4" TRS
connections, and barrier strip terminals with ground lift provision. The MFA-8000
model is also Ashly PowerCard compatible for other input option possibilities.
Output connectors include both Speakon and professional five-way binding posts.
bullet High power output with efficient power supply and output stage
bullet Extensive protection from signal and load faults
bullet Modular construction for reliability and serviceability

POWER OUTPUT
MFA8000
(per channel, both channels driven at 1kHz, <.1%THD)
8 Ohms: 750 Watts RMS
4 Ohms: 1200 Watts RMS
2 Ohms: 1500 Watts RMS

(bridged mono mode)
8 Ohms: 2400 Watts RMS
4 Ohms: 3000 Watts RMS

(per channel from 20Hz-12kHz*, <.25%THD)
8 Ohms: 720 Watts RMS
4 Ohms: 1100 Watts RMS

* Protection will prevent full output above 12kHz.

FREQUENCY RESPONSE
+/-0.2dB 20Hz-20kHz
+/-3dB 8Hz-100kHz

TOTAL HARMONIC DISTORTION
<.025% (rated power, 8 Ohms, 1kHz); <.25% (rated power, 8 Ohms, 12kHz)

OUTPUT HUM AND NOISE
-105dB referenced to full output (20Hz-20kHz, unweighted)

DAMPING FACTOR
>200 (8 Ohms, 20Hz-1kHz)

CROSSTALK
-90dB (20Hz-1kHz)

INPUT SENSITIVITY
1 Volt RMS (MFA8000), .81Volt RMS (MFA6000) for full output

VOLTAGE GAIN
80X (38dB)

INPUT IMPEDANCE
20kOhms, balanced

AMPLIFIER PROTECTION
Fuseless short circuit protection, DC, ultrasonic and RF protection,
Advanced thermal protection

LOAD PROTECTION
Fuseless short-circuit protection, turn-on delay with level-up ramp,
ultrasonic limiting, clip limiting

COOLING
Forced-air with two-speed fan

INDICATORS
11 segment level meters with true-clipping red LED. Green "limit" LED
indicates when electronic attenuator is active. Yellow "therm" LED
indicates high operating temperature. Red "protect" LED indicates when
output protect relay opens.

POWER REQUIREMENTS (typical stereo operation, 4 Ohm load)
MFA8000 - 120VAC, 50-60Hz (240VAC available) 1.2A idle, 12A max.

SIZE
19"W x 5.25"H x 16.5"D

Price: $1,475.00
Buy Product Online | Visit Store Home
   


 

  Return To The Installation Shop.com

 

 

e-commerce software
E-commerce powered by MonsterCommerce shopping carts.